Search results for " Substations"
showing 7 items of 7 documents
Simple Circuit Models for Studying Global Earthing Systems
2007
The paper proposes three simple circuit models for the simulation of the behaviour of a global earthing system during different fault events. The models allow one the evaluation of the maximum earth potential rise at every possible fault location and for every possible fault event. The three considered fault events are: single-line-to-earth fault inside a MV/LV substation, double-earth-fault in a MV line, single-line-to-earth fault inside a HV/MV station. After having illustrated the hypotheses at the basis of the study, the circuit models for the three fault events are presented and a numerical example shows how to use them in order to check the "global safety" of the interconnected earthi…
Experimental EMF characterization of a secondary substation
2015
This paper presents the results of the experimental EMC characterization of a new medium/low voltage (MV/LV) secondary substation, which was developed in the framework of the research project "NEW CAB ELARC". It has two MV/LV transformers, with total rated power of 1000 kVA. To perform the experimental characterization, firstly an analysis was performed of the Italian and European standards recommendations. Different approaches were highlighted and the most appropriate procedures were identified for the measurement of the magnetic fields emissions, at power systems frequency (50 Hz) in steady-state conditions. A dedicated test lab was set up for the secondary substation characterization. Th…
On the hazardous situations due to the presence of HV/MV substations in urban areas
2017
The paper focuses on the hazardous situations that can rise in urban areas in case of earth fault inside a High Voltage/Medium Voltage station. IEEE and IEC/EN Standards and technical documents are examined and discussed, in order to propose some practical guidelines for a safe integration of such installations in contexts characterized by the presence of low voltage systems and not trained persons.
The Quest for Global Safety
2007
The authors present a systematic study on the factors that have influence on the establishment of the safety conditions ensuring the rise of Global Earthing Systems. Starting from the definition of Global Earthing System given by CENELEC Document HD 637 SI and from the results of the studies done on the last years on the interconnected earthing systems inside MV networks, the paper proposes some directions of deepening on the topic of Global Safety. Some of the themes whom the paper deals with are: the correct definition of proximity, interconnection and quasi-equipotentiality of the earth electrodes belonging to a Global Earthing System; the influence of the presence of HV/MV stations on h…
Fall of Potential Measurement of the Earth Resistance in Urban Environments: Accuracy Evaluation
2019
Both Standards EN 50522 and IEEE 81 propose the fall of potential method (FPM) to carry out the measurement of the resistance to earth ( $R_{\text{ES}}$ ) of an earthing system (ES). However, in urban areas, the recommended distances between the ES and auxiliary electrodes are not easy to respect, due to the presence of buildings and tarmac. Furthermore, unknown buried metallic parts and interconnections among ESs could modify the earth potential profile of the area, affecting the measurement results. In this paper, the key-issues that influence the measured $R_{\text{ES}}$ when the FPM is used in an urban environment are presented. A parametric analysis, carried out with Comsol Multiphysic…
Safety Concerns on Ground Fault Application Transfer Phenomenon in HV Installations
2007
When a fault to ground occurs in HV/MV substations supplied by a combined overhead-cable line, most of the fault current can be transferred and injected into the soil several kilometers far away from the fault location. This phenomenon is called "fault application transfer" and mostly concerns transition stations, where cables are connected to the overhead line. If the transition station is a dead-end steel pole structure, usually accessible to the general public, the local ground electrode could be inadequate to maintain ground potential rise within safety limits. Hence, dangerous touch and step voltages may appear at exposed locations. In the paper results of various computer simulations …
A study of the behaviour of earth electrodes connected together in resonant earthed neutral systems
2005
Inside urban areas the earth electrodes of the MV/lv substations are often electrically connected together so as to form a single extended earthing system. The advantages of the realization of an extended earthing system are the reduction of the current that each substation earth electrode injects in the soil during the fault and a better uniformity of the voltages to earth inside the urban area. In previous works, models for the study of extended earthing systems have been proposed. These models were valid for the case of single-line-to earth fault in isolated neutral MV networks. In this paper, the extended earthing system is analyzed in the case of a resonant earthed neutral MV network. …